FIRE & GAS

PLC-SAFETYNET & FIRE DETECTORS-SIL 2

Project Info:

FIRE AND GAS DETECTION SYSTEMS TEXPETROL,DELIVERING TOP QUALITY

TEXPETROL, Inc. as Solution Provider of GE-IP offers the best solution for the protection of life of workers and asset of the Oil and Gas Industry. We offer a complete integration of Fire and Gas Detection Systems using a PLC of General Electric with a very low probability to fail in demand, in our integration we use a SAFETYNET – SIL 2, together with other devices with the same safety level and /or connected under supervision and monitoring and self-diagnostic of good performance. Our integration can be used in any place of Oil and Gas Industry, such as UP-STREAM, MID-STREAM and DOWNSTREAM, OFF-SHORE or ON-SHORE.

Our Fire and Gas Detection Systems is integrated mainly, but not limited, for the following devices:

  • PLC- SAFETYNET – SIL 2
  • FIRE DETECTORS

Indeed, our integration can be located physically in a Hazardous Area Classified as Class I, Division 2, without purge system in our cabinet where the devices such as the PLC, Touch Screen Monitor and Accessories are installed. Additionally, if the fire and gas detection system must be installed in a remote area is out of the Electrical Grid, we can supplier a Solar Panel system to supply the electrical energy required with Battery Backup and/or UPS.If you need to protect the people, the properties and the environment against an accident, then you must use a reliable system and TEXPETROL, Inc. can supply to you.

  • GAS DETECTORS
  • SIRENS, HORNS, SOUNDERS ALARMS
  • STROBE LIGHT, INDICATORS LIGHTS ALARMS
  • MANUAL ALARM CALL POINT ALARM
  • HMI/DISPLAY
  • INTEGRATION/ ASSEMBLY

PLC-SAFETYNET- SIL 2

PAC 8000 SAFETYNET

As a GE-IP Solution Providers, TEXPETROL, Inc. offers the PAC8000 SAFETYNET for the fire and gas detection application. It is a suitable investment for a well-founded SIL 2 system used to reduce the risk of failing when it is required. The SAFETYNET is certified as suitable for use in SIL 2 safety functions by TÜV Rheinland, additionally PAC8000 SAFETYNET incorporates the latest design techniques to achieve compliance with IEC 61508 and IEC 61511.

It is a rugged and trustworthy equipment used around the world. With our solution is a saving money installation because we can place the cabinet in the Field near of instrument as close as Class I, Div.2 classification area and additionally SAFETYNET provides a high level reliability of internal and automatic diagnostics – achieving SIL 2 without redundant I/O modules or controllers. Others must have double I/O to achieve SIL 2, less cabling and electrical accessories during the installation means save money with our systems.

PDF-SAFETYNET SIL2 Fire and Gas App

FIRE DETECTORS- SIL 2

FLAME DETECTION

The main feature that must be looking for is the reliability of the detectors, therefore avoid the false alarm must be the goal. For that reason, existing UV sensors and IR sensors, and they are monitoring the wavelength outside of range of the sun solar to avoid be triggered when the sun goes directly to the sensor. Other point the fire has a wide composition of wavelength, it goes since UV until IR, therefore the manufacturers design a composition of several sensors and different types and an algorithm where only the combination of the IR and UV Sensors are activated. It is recommended that the detector has at least two Infrared detectors to detect the flicker of the flame, because only one can be misled and generate a false alarm.

That is the reason which recommend to use a Fire Detectors with different Sensors Technologies (UV-IR) to cover the range out the Solar wavelength of the flame and at least two Infrared sensors with different wavelength, in this way the risk of false alarm is deeply reduced. It is very important that the detectors must self-diagnostic type and at least SIL 2 approval

PDF-Fire Detectors TYCO SIMTRONICS PDF-Multi-Spectrum IR and UV and IR IOM PDF-SIL Certificate MultiFlame Detector PDF-Multi-Spectrum UV-2IR Flame Detector TYCO SIMTRONICS PDF-Multi-Spectrum-IR3 Flame Detector TYCO SIMTRONICS PDF-Flame Detection TYCO SIMTRONICS

GAS DETECTORS-SIL 2

Blog Single

GAS DETECTION

For the Gas Detection, one of the features most important of the sensors of the gas detectors is the precision and reliabilty. There are two main technologies:

1-Catalytic Bead: A small coil wire of Platinum is covered for a layer catalytic which reacts in presence of Hydrocarbon Gas increasing the temperature and changing the electrical resistance, this element is placed in a Bridge Wheatstone and unbalanced will be proportional to amount of hydrocarbon gas. We found some information done by specialists of General Monitors (Dr. Shankar Baliga, Ph.D. in Physics from Ohio State University) indicating:

“Although catalytic bead sensors have been in use for decades, the technology has some drawbacks. One critical limitation is the inability to operate in an environment deficient in oxygen since the bead requires efficient oxidation of hydrocarbon gas; oxygen levels impact oxidation efficiency; and hence, the sensor’s accuracy. Another drawback is the possibility of sensor poisoning by chemical compounds such as silicones and sulfur compounds leading to a decline in catalytic activity. Contamination of the sensor is also possible, for example, by trapping of dust in the flame arrestor or exposure to heavy oils and greases. Contamination can show up during normal maintenance of the system as an increase in the response time to calibration, recovery time after exposure, and loss of sensitivity.

Since these conditions can occur without warning to the operator, electro-catalytic hydrocarbon sensors are not fail-to-safe; fail-to-safe in this instance implies the sensor’s ability to communicate its dysfunctional status to the operator for the various failure modes. For example, the operator may not know the poisoned status of the catalytic bead until calibration gas is required. This results in an increase in calibration intervals in areas where poisoning agents are suspected to exist”.

Blog Single

2-Infrared: It : It is required an infrared emitter and Infrared receptor, The Hydrocarbon Gas absorbs the Infrared energy, The IR method of measuring gas concentration is based on the absorption of IR radiation at certain wavelengths as the radiation passes through a volume of the gas. IR gas sensing technology provides for fail-to-safe operation in contrast to electro-catalytic sensors since optical sensing is an active technology, which continuously monitors for sensor faults and communicates them to the user.

This is achieved chiefly through the use of the second or reference wavelength. IR detectors are also immune to poisoning, resistant to corrosion, can operate in a deficit or surplus of oxygen, and do not suffer from reduction in sensor life on repeated exposure to gas. With the sophisticated optical and electronic designs currently being used, the detectors are factory calibrated and virtually maintenance free. This is particularly desirable when sensors must be located in inaccessible areas and cannot be easily calibrated on a periodic basis.

GAS DETECTORS- SIL 2

GAS DETECTION

TexPetrol, Inc. uses infrared for Gas Detection for the reliability and precision. The infrared gas detectors used by Texpetrol differ from all other models, because they utilize silicon based solid-state infrared sources. The complete opto-mechanical design and construction is so stable that an ultra-fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs. It is very important that the detectors must self-diagnostic type and at least SIL 2 approval For retrofit applications, a bridge interface is available allowing the detector to be connected directly to catalytic systems, using the existing cabling and control modules.”

PDF-IR Point Gas Detector UL TYCO SIMTRONICS SIL 2 y 3 PDF-IR Point Gas Detector CSA TYCO SIMTRONICS SIL 2 y 3 PDF-IR GD10-P00 Manual de Operacion-Español PDF-GD10 Handheld Terminal Manual TYCO SIMTRONICS PDF-IR GD10 SIL 2 y 3 Certification PDF-IR GD10 CSA Certification PDF-IR GD10 UL Certification

SIRENS, HORNS, BELL, SOUNDERS ALARMS

For Fire and Gas Detection System the Sound Alarm is very important to avoid the losing of life, this signal is vital for the operator in the field. One of the most important features the customer needs to be aware is the sound level, we need the sound emitted by device must be superior than the noise in the industrial environment where the operators would be working.

The material must be done to avoid corrosion and the capability to be submitted for supervision and monitoring. If the device is not SIL 2, It would be necessary to increase the amount of testing to check the good performance. A certify specialist in Safety Instrument Systems could indicate the number of testing required for the system to keep the SIL 2 Level. We have a variety of options to be installed in Electrical Classification Area Class I - Div.2, Class 1 - Div. 1 or Harsh Industrial Environment as General Purpose.

PDF-MEDC Crouse-Hind EATON Signaling Alarm PDF-MEDC Cooper Siren Souder DB3BUL PDF-MEDC EATON Sounder DB12 Harsh Industrial Environments PDF-MEDC EATON Sounder DB1 Class I Div 1

STROBE LIGHT, INDICATORS LIGHTS ALARMS

These high output certified beacons have been designed for use in potentially explosive atmospheres and harsh environmental conditions. The enclosures are suitable for use offshore or onshore, where lightweight combined with corrosion resistance is required. The beacon house material is manufactured completely from a UV stable, glass reinforced polyester. Stainless steel screws and mounting bracket are incorporated ensuring a totally corrosion free product.

PDF-MEDC Crouse-Hind EATON Signaling Alarm PDF-MEDC Cooper Siren Souder DB3BUL PDF-MEDC EATON Sounder DB12 Harsh Industrial Environments PDF-MEDC EATON Sounder DB1 Class I Div 1 PDF-MEDC EATON Sounder DB1 Class I Div 1

MANUAL ALARM CALL POINT ALARM

Manual alarm call points are designed for the purpose of raising an alarm manually once verification of a fire or emergency condition exists, by operating the push button or break glass the alarm signal can be raised. The PH1 double action pull handle call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where light weight combined with a high level of corrosion resistance is required.

PDF-MEDC PH1 Class 1 Div 1 PULL HANDLE CALL POINT PDF-MEDC SM87BG & SM87PB Class 1 Div 1 ALARM CALL POINTS

HMI–DISPLAYS

We offer a visualization solution which shows the status, layout, configuration, warning or alarm acknowledgment. We have alternatives for enclosure to be used indoor general purpose as NEMA 12 (Control room environment) or Outdoor corrosive area as NEMA 4X or Hazardous area as Class 1, Div.2. Lightweight screen can be placed in the door of the cabinet with wide range of sizes to cover the need required.

PDF-HMI Display GE-IP PDF-HAZARDOUS AREA PC WORKSTATION PDF-Internet Connection FLAME PROOF ZONE 1 PC

INTEGRATION/ ASSEMBLY

If you require a Complete Integration Solution for a Fire and Gas Detection System, TEXPETROL, Inc. is the right answer for your requirement, we have a specialist staff to prepare the Design, Drawings, Assembly, FAT, Delivery, Commissioning and Start up according with the standard and engineering required. These systems require a high level of expertise and detailed design and integration to accomplish successfully. FGDS must perform from detection of hazardous gases and /or fire up to an appropriate plant shutdown. A FGDS is critical to operate a plant safety and its efficiency and reliability is of greatest concern for plant operators and environmental authorities. Our reliability rests on the shoulders of our high quality equipment used in our integration

TEXPETROL Other Products:



Call us today for an Estimate at +1 (281) 880-4810 or Email us at sales@texpetrol.net

We strive to provide Our Customers with Top Notch Service with all our Oil & Gas products CONTACT US

TEXPETROL OIL & GAS

FIRE & GAS DETECTION